- 浩瀚固定污染源废气中NMHC测定甲烷毛细管柱HH-PLOT-Molecular sieve
详细信息
品牌:浩瀚 型号:HH-PLOT-Molecular sieve 加工定制:是 测量范围:ppm 测量对象:非甲烷总烃 控温范围:250 ℃ 尺寸:30000 mm 重量:0.02 Kg 甲烷:总烃 非甲烷总烃:环境空气 固定污染源废气:室内空气 焦炉煤气:增塑剂 炼厂气:零级空气发生器
浩瀚色谱(山东)应用技术开发有限公司采用十通阀、双定量环进样,双色谱柱分别分离两路气样,单FID检测器检测的方法测定固定污染源废气中的总烃、甲烷和非甲烷总烃.样品分析一次进样同时获得总烃和甲烷的数据,避免进样误差,大大节省了分析时间,具有操作简单、方法快速、重现性好等特点.
甲烷毛细管柱:
固定相:多孔层开口管分子筛柱或其他等效毛细管柱
规格:30m*0.53mm*25um
型号:HH-PLOT-Molecular sieve
应用:HJ 604-2017环境空气 总烃、甲烷和非甲烷总烃的测定 直接进样-气相色谱法
HJ 38-2017 固定污染源废气 总烃、甲烷和非甲烷总烃的测定 气相色谱法
HJ604-2011 环境空气 总烃的测定 气相色谱
GB-T 15263-94 环境空气 总烃的测定 气相色谱法
Combined with the actual situation of the monitoring of fixed pollution sources, the influencing factors of the determination of non-methane total hydrocarbons (NMHC) in the exhaust gas of pollution sources by gas chromatography are discussed. The study found that there is a difference in concentration between single standard gas and mixed standard gas when calibrating the same sample. The sampling method, the material and volume of the sampling container have a serious impact on the accuracy of the monitoring results. For this reason, it is necessary to more strictly regulate the sampling method of fixed pollution sources and increase the accuracy of the monitoring results of fixed pollution sources. At the same time, by comparing the definitions of NMHC and VOCs and existing methods, the relationship between the two and the numerical difference under the same conditions are analyzed in detail. Not inconsistent. In addition, the NMHC based on the FID response value cannot accurately and comprehensively reflect the degree of air organic pollution, and may cover up some organic pollution in the exhaust gas.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. uses ten-port valve, double loop sampling, double chromatographic columns to separate two gas samples, and single FID detector detection method to determine total hydrocarbons, methane and non-volatile gas in the exhaust gas of fixed pollution sources. Total hydrocarbons of methane. The data of total hydrocarbons and methane can be obtained at the same time for sample analysis, which avoids sampling errors and greatly saves analysis time. It has the characteristics of simple operation, fast method, and good reproducibility.
Methane capillary column:
Stationary phase: porous layer open-tube molecular sieve column or other equivalent capillary column
Specification: 30m*0.53mm*25um
Model: HH-PLOT-Molecular sieve
application:
HJ 604-2017 Ambient air Determination of total hydrocarbons, methane and non-methane total hydrocarbons Direct sampling-gas chromatography
HJ 38-2017 Determination of Total Hydrocarbons, Methane and Non-Methane Total Hydrocarbons in Waste Gases from Stationary Pollution Sources Gas Chromatography
HJ604-2011 Determination of Total Hydrocarbons in Ambient Air Gas Chromatography
GB-T 15263-94 Determination of Total Hydrocarbons in Ambient Air Gas Chromatography -
-
产品搜索
有影响力的客户
1.中国秦山核电站2.西安科技大学
3.西凤酒厂
4.南京工业大学
5.中国石油天然气股份有限公司
6.中国辐射防护研究所
7.中国石油大学
8.山东理工大学
9.南京工业大学化工学院
10.东南大学
11.徐州市质量技术监督局
12.惠州市石油产品质监局
13.山东兖矿集团
14.河南信阳师范化学化工学院
15.辽阳市质量技术监督局
16.河北高碑店市技术监督局
17.山东化工职业学院
18.山东理工大学
19.沈阳化工研究院
20.吉林市质量技术监督局
21.长庆油田延安采油厂
22..胜利油田
23.宝鸡质量技术监督局
24.杨凌质监局
25.华东交通大学
26.太原电力高等专科学校
27.南京林业大学
28.山东农科院植物保护研究所
29.淮北师范大学
30.郑州大学
31.央企--中储粮集团公司
32.出口--蒙古国
33.中国铁路总公司
34.南通大学
35.山西农业大学
36.华东理工大
37.央企--中纺集团