- 浩瀚中国药典2020年版二氧化碳分析玻璃球色谱柱HH-BLQ
详细信息
品牌:浩瀚 型号:HH-BLQ 加工定制:是 测量范围:ppm 测量对象:药典二氧化碳 控温范围:300 ℃ 尺寸:1000 mm 重量:0.02 Kg 药典:二氧化碳 碳氢化合物:非甲烷总烃 石墨化碳黑:零级空气发生器 氧化铝:液化石油气 GDX-105:环氧乙烷 中国药典2020年版
二氧化碳
性状
本品为无色气体;无臭;水溶液显弱酸性反应。本品1容在常压20℃时,能溶于水约1容中。
鉴别
(1)取本品,通入氢氧化钡试液中,即生成白色沉淀;沉淀能在醋酸中溶解并发生泡沸。(2)本品能使火焰熄灭。(3)本品的红外光吸收图谱应与对照的图谱(图1)一致(通则0402)
碳氢化合物照气相色谱法(通则0521)测定供试品气体取本品,即得对照品气体取甲烷含量为0.0020%的气体(以氮气为稀释剂)。色谱条件用玻璃球为填料的色谱柱(4mm×0.8m,80目);柱温为110℃;进样口温度为110℃;检测器为火焰离子化检测器,温度为120℃测定法精密量取供试品气体与对照品气体,分别注入气相色谱仪,在净化温度为360℃时测得的峰面积为相应空白值;精密量取供试品气体与对照品气体,分别注入气相色谱仪,测定峰面积,减去相应空白值后的峰面积为校正峰面积限度按外标法以校正峰面积计算,含碳氢化合物(以甲烷计)不得过0.0020%。
名称:填充柱
规格:1m*1/8,80目
型号:HH-BLQ
应用:中国药典2020版二氧化碳中碳氢化合物的测定
适用于:安捷伦7890,岛津2010,2014,赛默飞TRACE 1310
Chinese Pharmacopoeia 2020 Edition
carbon dioxide
Traits
This product is a colorless gas; odorless; the aqueous solution shows a weak acid reaction. This product can dissolve in about 1 volume of water when 1 volume is at 20℃ under normal pressure.
Identify
(1) Take this product and pass it into the barium hydroxide test solution to form a white precipitate; the precipitate can be dissolved in acetic acid and boiled. (2) This product can extinguish the flame. (3) The infrared light absorption spectrum of this product should be consistent with the control spectrum (Figure 1) (General Rule 0402)
Hydrocarbons are determined according to gas chromatography (General Principle 0521). Take this product as the test sample gas, that is, the reference sample gas should be a gas with a methane content of 0.0020% (with nitrogen as a diluent). Chromatographic conditions use a chromatographic column filled with glass balls (4mm×0.8m, 80 mesh); the column temperature is 110℃; the temperature of the injection port is 110℃; the detector is a flame ionization detector, and the temperature is 120℃. The method is precise. Measure the test gas and reference gas and inject them into the gas chromatograph respectively. The peak area measured when the purification temperature is 360°C is the corresponding blank value; accurately measure the test gas and reference gas and inject them into the gas chromatograph. The peak area is determined by the instrument, and the peak area after subtracting the corresponding blank value is the calibrated peak area limit. The peak area is calculated by the external standard method, and the hydrocarbon content (calculated as methane) shall not exceed 0.0020%.
Name: Packed column
Specification: 1m*1/8, 80 mesh
Model: HH-BLQ
Application: Determination of Hydrocarbons in Carbon Dioxide of Chinese Pharmacopoeia 2020 Edition
Applicable to: Agilent 7890, Shimadzu 2010, 2014, Thermo Fisher TRACE 1310 -
供应商的其他相关信息
查看更多
-
产品搜索
有影响力的客户
1.中国秦山核电站2.西安科技大学
3.西凤酒厂
4.南京工业大学
5.中国石油天然气股份有限公司
6.中国辐射防护研究所
7.中国石油大学
8.山东理工大学
9.南京工业大学化工学院
10.东南大学
11.徐州市质量技术监督局
12.惠州市石油产品质监局
13.山东兖矿集团
14.河南信阳师范化学化工学院
15.辽阳市质量技术监督局
16.河北高碑店市技术监督局
17.山东化工职业学院
18.山东理工大学
19.沈阳化工研究院
20.吉林市质量技术监督局
21.长庆油田延安采油厂
22..胜利油田
23.宝鸡质量技术监督局
24.杨凌质监局
25.华东交通大学
26.太原电力高等专科学校
27.南京林业大学
28.山东农科院植物保护研究所
29.淮北师范大学
30.郑州大学
31.央企--中储粮集团公司
32.出口--蒙古国
33.中国铁路总公司
34.南通大学
35.山西农业大学
36.华东理工大
37.央企--中纺集团