| 品牌:Haohan | | 型号:HH-NMHC-I | | 加工定制:是 | |
| 测量范围:ppm | | 测量对象:非甲烷总烃 | | 控温范围:300 ℃ | |
| 尺寸:1000 mm | | 重量:0.02 Kg | | 环境空气非甲烷总烃:固定污染源废气 | |
| 碳氢化合物:乙酸 | | 石墨化碳黑:零级空气发生器 | | 氧化铝:液化石油气 | |
| GDX-105:407有机担体 | | | | | |
浩瀚色谱(山东)应用技术开发有限公司采用氢火焰离子化检测器气相色谱法测定环境空气中非甲烷总烃。方法的检出限:总烃为0.02mg/m3,甲烷为0.02 mg/m3,非甲烷总烃为0.02 mg/m3。变异系数:总烃为0.65%,甲烷为0.55%,非甲烷总烃为3.06%。加标回收率:总烃为101.2%~102.7%,甲烷为100.7%~101.8%。该方法可行性良好,适用于环境空气中非甲烷总烃的测定。
名称:甲烷专用柱
规格:1m*1/8
型号:HH-NMHC-I
应用:直接测定环境空气及固定污染源废气中非甲烷总烃的含量
单柱反吹法直接测定环境空气中非甲烷总烃,无需差减,效率高,定量准确可靠。
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses hydrogen flame ionization detector gas chromatography to determine non-methane total hydrocarbons in ambient air. The detection limits of the method were as follows: total hydrocarbons were 0.02 mg/m3, methane was 0.02 mg/m3, and non-methane total hydrocarbons were 0.02 mg/m3. Coefficient of variation: total hydrocarbons were 0.65%, methane was 0.55%, and non-methane total hydrocarbons were 3.06%. The recovery rate of standard addition: the total hydrocarbons are 101.2%~102.7%, and the methane is 100.7%~101.8%. The method is feasible and suitable for the determination of non-methane total hydrocarbons in ambient air.
Name: methane column
Specifications: 1m*1/8
Model: HH-NMHC-I
Application: Direct determination of the content of non-methane total hydrocarbons in ambient air and waste gas from stationary pollution sources
The single-column backflushing method directly measures non-methane total hydrocarbons in ambient air without differential subtraction, with high efficiency, accurate and reliable quantification.