• haohan ¹Ì¶¨ÎÛȾԴ·ÏÆø ×ÜÌþ¡¢¼×ÍéºÍ·Ç¼×Íé×ÜÌþµÄ²â¶¨ÍÑ»îëϸ¹Ü¿ÕÖùHH-THC-30

    ÏêϸÐÅÏ¢

     Æ·ÅÆ£ºhaohan  ÐͺţºHH-THC-30  ¼Ó¹¤¶¨ÖÆ£ºÊÇ  
     ²âÁ¿·¶Î§£ºppm  ²âÁ¿¶ÔÏ󣺷Ǽ×Íé×ÜÌþ  ¿Øη¶Î§£º300 ¡æ 
     ³ß´ç£º30000 mm ÖØÁ¿£º0.02 Kg ¹Ì¶¨ÎÛȾԴ·ÏÆø ×ÜÌþ¡£º·Ç¼×Íé×ÜÌþ  
     »·¾³¿ÕÆø£º¾»»¯×°Öà  Ê¯Ä«»¯Ì¼ºÚ£ºÁ㼶¿ÕÆø·¢ÉúÆ÷  Ñõ»¯ÂÁ£ºÒº»¯Ê¯ÓÍÆø  
     GDX-105£º407Óлúµ£Ìå    
    ·Ç¼×Íé×ÜÌþ£¨NMHC£©Ö¸³ý¼×ÍéÒÔÍâ»Ó·¢ÐÔ̼Ç⻯ºÏÎÆäÖÐÖ÷ÒªÊÇC2—C8£©µÄ×ܺÏ,³¤ÆÚÒÔÀ´Ò»Ö±ÊÇ»·¾³¿ÕÆø¼à²âµÄÒ»ÏîÖØÒªÖ¸±ê,ÎÒ¹ú¡¶´óÆøÎÛȾÎï×ÛºÏÅŷűê×¼¡·GB16927—1996¹æ¶¨·Ç¼×Íé×ÜÌþµÄ³§½çŨ¶È±ê׼Ϊ4 mg·m-3,¡¶¹Ì¶¨ÎÛȾԴÅÅÆøÖзǼ×Íé×ÜÌþµÄ²â¶¨ÆøÏàÉ«Æ×·¨¡·¡£


    ºÆå«É«Æ×£¨É½¶«£©Ó¦Óü¼Êõ¿ª·¢ÓÐÏÞ¹«Ë¾ÓÃÆøÏàÉ«Æ×ÒÇÅäË«Çâ»ðÑæ¼ì²âÆ÷,˫ëϸ¹ÜÖùÖù·ÖÎö¹Ì¶¨ÎÛȾԴÅÅÆøÖÐ×ÜÌþ,¼×Íé,Ñõ·å´Ó¶øµÃµ½·Ç¼×Íé×ÜÌþ(NMHC)º¬Á¿.µ±É«Æ×½øÑùÁ¿Îª1.0 mLʱ,·½·¨µÄ¼ì³öŨ¶ÈΪ4×10-2mg/m3,·½·¨µÄ¶¨Á¿¼ì¶¨Å¨¶È·¶Î§Îª0.12¡«32 mg/m3.×ÅÖؽéÉܶÀÌصıê×¼ÆøÌåµÄÅäÖÆ·½·¨¼°½øÑù·½·¨,±£Ö¤Á˷Ǽ×Íé×ÜÌþ(NMHC)²âÊÔµÄ׼ȷÐÔ.
     

    Ãû³Æ£º×ÜÌþëϸ¹ÜÉ«Æ×Öù

    ¹Ì¶¨ÏࣺÍÑ»îµÄëϸ¹Ü¿ÕÖù

    ¹æ¸ñ£º30m*0.53mm

    ÐͺţºHH-THC-30

    ²ÄÖÊ£ºÈÛÈÚʯӢ

    Ó¦ÓãºHJ 38-2017 ¹Ì¶¨ÎÛȾԴ·ÏÆø ×ÜÌþ¡¢¼×ÍéºÍ·Ç¼×Íé×ÜÌþµÄ²â¶¨ ÆøÏàÉ«Æ×·¨

     
    Non-methane total hydrocarbons (NMHC) refer to the sum of volatile hydrocarbons (mainly C2-C8) other than methane. It has been an important indicator of ambient air monitoring for a long time. GB16927-1996 stipulates that the factory boundary concentration standard of non-methane total hydrocarbons is 4 mg·m-3, "Determination of non-methane total hydrocarbons in stationary pollution source exhaust gas by gas chromatography".


    Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses a gas chromatograph equipped with a double hydrogen flame detector and a double capillary column to analyze the total hydrocarbons, methane and oxygen peaks in the exhaust gas of fixed pollution sources to obtain the content of non-methane total hydrocarbons (NMHC). When When the chromatographic injection volume is 1.0 mL, the detection concentration of the method is 4×10-2mg/m3, and the quantitative detection concentration range of the method is 0.12¡«32 mg/m3. The preparation method and injection method of the unique standard gas are emphasized. , to ensure the accuracy of the non-methane total hydrocarbons (NMHC) test.

    Name: Total Hydrocarbon Capillary Column

    Stationary phase: deactivated capillary empty column

    Specifications: 30m*0.53mm

    Model: HH-THC-30

    Material: Fused Silica

    Application: HJ 38-2017 Waste gas from stationary pollution sources-Determination of total hydrocarbons, methane and non-methane total hydrocarbons-Gas chromatography
  • ÁôÑÔ

    *ÏêϸÐèÇó£º
    *ÊÖ  »ú£º
    Áª ϵ ÈË£º
    µç    »°£º
    E-mail£º
    ¹«  ˾£º
    ¡¶¹ÈÆÙ·þÎñÌõ¿î¡·¡¶Òþ˽Õþ²ß¡·
ºÆå«É«Æ×£¨É½¶«£©Ó¦Óü¼Êõ¿ª·¢ÓÐÏÞ¹«Ë¾ µç»°£º0632-5667636 ÊÖ»ú£º13963221227 µØÖ·£º ëøÖÝÊУ¨ÉÌÎñ²¿ºÍ¼¼Êõ²¿£©£»
ÄÚÈÝÉùÃ÷£º¹ÈÆÙΪµÚÈý·½Æ½Ì¨¼°»¥ÁªÍøÐÅÏ¢·þÎñÌṩÕߣ¬¹ÈÆÙ£¨º¬ÍøÕ¾¡¢¿Í»§¶ËµÈ£©ËùչʾµÄÉÌÆ·/·þÎñµÄ±êÌâ¡¢¼Û¸ñ¡¢ÏêÇéµÈÐÅÏ¢ÄÚÈÝϵÓɵêÆ̾­ÓªÕß·¢²¼£¬ÆäÕæʵÐÔ¡¢×¼È·ÐԺͺϷ¨ÐÔ¾ùÓɵêÆ̾­ÓªÕ߸ºÔð¡£¹ÈÆÙÌáÐÑÄú¹ºÂòÉÌÆ·/·þÎñÇ°×¢Òâ½÷É÷ºËʵ£¬ÈçÄú¶ÔÉÌÆ·/·þÎñµÄ±êÌâ¡¢¼Û¸ñ¡¢ÏêÇéµÈÈκÎÐÅÏ¢ÓÐÈκÎÒÉÎʵģ¬ÇëÔÚ¹ºÂòǰͨ¹ý¹ÈÆÙÓëµêÆ̾­ÓªÕß¹µÍ¨È·ÈÏ£»¹ÈÆÙÉÏ´æÔÚº£Á¿µêÆÌ£¬ÈçÄú·¢ÏÖµêÆÌÄÚÓÐÈκÎÎ¥·¨/ÇÖȨÐÅÏ¢£¬ÇëÔÚ¹ÈÆÙÊ×Ò³µ×À¸Í¶ËßͨµÀ½øÐÐͶËß¡£