• 浩瀚固定污染源废气中三甲胺的含量测定胺专用毛细管柱HH-Tamine30

    详细信息

     品牌:浩瀚  型号:HH-Tamine30  加工定制:是  
     测量范围:ppm  测量对象:固定污染源废气中三甲胺  控温范围:300 ℃ 
     尺寸:1500 mm 重量:0.02 Kg 碳分子筛:TDX-01  
     TDX-02:苯系物  医疗器械:环氧乙烷  甲烷:甲醇  
     赛默飞:安捷伦  甲酸:消毒剂  :氙  
     MTBE:TENAX-TA    

    浩瀚色谱(山东)应用技术开发有限公司,按照HJ/T55或GB/T16157的相关规定,用固定量0.12mol·L^-1盐酸溶液吸收采集固定污染源废气中三甲胺。分取样品溶液10.00mL,移至顶空瓶中,加入氯化钠3.2g和硫酸钾1.0g,并用微量注射器加入质量分数为50%的NaOH溶液500μL和氨水100μL,立即密封顶空瓶,在顶空平衡温度为80℃,平衡时间为30min的条件下进行顶空采样。选择HH-Tamine30胺专用石英毛细管色谱柱进行三甲胺及其他5种研究的脂肪胺类化合物的定量分离,采用氢火焰离子化检测器(FID)进行检测。分别按HJ/T55及GB/T16157规定的方法各取三甲胺标准气体20L,分别进行7组平行试验,测得前一采样方法的检出限[tn-1,0.99)×s]为0.004mg·m^-3,后一采样方法的检出限[tn-1,0.99)×s]为0.02mg·m^-3。另取高浓度(0.510μmol·mol^-1)、中浓度(0.102μmol·mol^-1)及低浓度(0.0102μmol·mol^-1)等3种浓度的三甲胺标准气体,按规定方法采样并分析6次,计算得三甲胺的回收率在90.1%~108%之间,测定值的相对标准偏差(n=6)在2.2%~6.7%之间。应用此方法分析实际样品,测定结果表明该方法能满足国家标准GB14554-93及天津市和上海市两地方标准对恶臭污染物排放的规定,并配合上述标准的执行。

     

    名称:HH-Tamine30毛细管柱
    规格:30m*0.32mm*5.0um
    *高使用温度:280°C
    编号:20220923001
    应用顶空-气相色谱法测定固定污染源废气中三甲胺的含量

     
     
     
     

    In accordance with HJ/T55 or GB/T16157, Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses a fixed amount of 0.12mol · L ^ - 1 hydrochloric acid solution to absorb and collect trimethylamine from waste gas of fixed pollution sources. Take 10.00mL of sample solution, transfer it to a headspace bottle, add 3.2g of sodium chloride and 1.0g of potassium sulfate, and use a micro syringe to add 500 NaOH solutions with a mass fraction of 50% μ L and ammonia 100 μ 50. Immediately seal the headspace bottle, and conduct headspace sampling under the condition that the headspace balance temperature is 80 ℃ and the balance time is 30min. The specific quartz capillary column for HH-Tamine30 amine was selected for quantitative separation of trimethylamine and other five fatty amine compounds studied, and hydrogen flame ionization detector (FID) was used for detection. Take 20L of trimethylamine standard gas respectively according to the methods specified in HJ/T55 and GB/T16157, conduct 7 groups of parallel tests respectively, and measure the detection limit [tn-1, 0.99] of the previous sampling method × s] 0.004mg · m ^ - 3, detection limit of the later sampling method [tn-1, 0.99) × s] Is 0.02mg · m ^ - 3. Another high concentration (0.510 μ Mol · mol ^ - 1), medium concentration (0.102 μ Mol · mol ^ - 1) and low concentration (0.0102 μ Three concentrations of trimethylamine standard gas such as mol · mol ^ - 1) were sampled and analyzed for 6 times according to the specified method. The calculated recovery of trimethylamine was 90.1%~108%, and the relative standard deviation (n=6) of the measured value was 2.2%~6.7%. Using this method to analyze actual samples, the determination results show that this method can meet the requirements of the national standard GB14554-93 and the local standards of Tianjin and Shanghai on the emission of odor pollutants, and cooperate with the implementation of the above standards.




    Name: HH-Tamine30 capillary column

    Specification: 30m * 0.32mm * 5.0um

    Maximum operating temperature: 280 ° C

    No.: 20220923001

    Determination of Trimethylamine in Waste Gas from Stationary Pollution Sources by Headspace Gas Chromatography