• haohan丁酸氢化可的松乳膏中三氯叔丁醇含量测定毛细管柱HH-1701

    详细信息

     品牌:haohan  型号:HH-1701  加工定制:是  
     规格:30m*0.25mm*0.25um  长度:30000  内径:0.25  
     膜厚:2.0  30m*0.25mm*0.25um:丁酸氢化可的松乳膏  三氯叔丁醇:氧化亚氮  
     有机磷:有机氯  碳氢化合物:分子筛  3%Dexil-300/Chromosorb W AW D:二氧化碳  
    浩瀚色谱(山东)应用技术开发有限公司,用气相色谱法测定丁酸氧化可的松乳膏中三氯叔丁醇含量.方法 采用HH-1701毛细管柱,30 m×0.25 mm,0.25 μm),程检测器为氢火焰离子化检测器(FID),温度260℃,进样口温度230℃,载气为氮气,流速5.0 mL/min,进样量1μL.结果 三氯叔丁醇进样量在0.010~0.111μg(r=0.999 9)范围内有良好的线性关系,平均加样回收率(n=9)100.45%. 此法灵敏度高,操作简便,准确,可用于测定丁酸氢化可的松乳膏中三氯叔丁醇的含量.
     

    名称:毛细管柱

    规格:30m*0.25mm*0.25um

    型号:HH-1701

    应用:GB/T 29676-2013 化妆品中三氯叔丁醇的测定 气相色谱-质谱法

     

     

    本标准规定了化妆品中三氯叔丁醇的气相色谱-质谱测定方法。
    本标准适用于膏霜、水剂、散粉、香波、唇膏类化妆品中三氯叔丁醇的测定。
    本标准对于三氯叔丁醇的检出限为0.15mg/kg,定量限为0.4mg/kg。

     

     

    适用于:

    安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890

    岛津GC-14C,GC-2010,GC-2014,GC-2030

    赛默飞1310,1300,1610,1600

    瓦里安3800系列

    布鲁克PE580,590,680,690

    磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓


     



    Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses gas chromatography to determine the content of trichlorotert butanol in butyrate oxidized cortisone cream Method: HH-1701 capillary column, 30 m × 0.25 mm, 0.25 μ m), hydrogen flame ionization detector (FID), temperature 260 ℃, injection port temperature 230 ℃, carrier gas nitrogen, flow rate 5.0 mL/min, injection volume 1 μ L The results showed that there was a good linear relationship between the injection amount of trichlorotert butanol in the range of 0.010-0.11 μ g (r=0.999 9 9), and the average recovery rate (n=9) was 100.45%. This method has high sensitivity, simple operation, and accuracy, and can be used to determine the content of trichlorotert butanol in hydrocortisone butyrate cream
    Name: Capillary Column
    Specification: 30m * 0.25mm * 0.25um
    model: HH-1701
    Application: GB/T 29676-2013 Determination of Trichlorotert Butyl Alcohol in Cosmetics Gas Chromatography Mass Spectrometry Method
    This standard specifies the gas chromatography-mass spectrometry method for the determination of trichlorotert butanol in cosmetics.
    This standard is applicable to the determination of tert butyl trichloride in cream, water, powder, shampoo, lipstick cosmetics.
    The detection limit for trichlorotert butanol in this standard is 0.15mg/kg, and the quantification limit is 0.4mg/kg.
    Applicable to:
    Agilent 490 online/portable, 48905890689088608890
    Shimadzu GC-14C, GC-2010,GC-2014,GC-2030
    Thermo Fisher Scientific 1310130016101600
    Varian 3800 Series
    Brooke PE580590680690
    Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao

     

  • 留言

    *详细需求:
    *手  机:
    联 系 人:
    电    话:
    E-mail:
    公  司:
    谷瀑服务条款》《隐私政策
浩瀚色谱(山东)应用技术开发有限公司 电话:0632-5667636 手机:13963221227 地址: 滕州市(商务部和技术部);
内容声明:谷瀑为第三方平台及互联网信息服务提供者,谷瀑(含网站、客户端等)所展示的商品/服务的标题、价格、详情等信息内容系由店铺经营者发布,其真实性、准确性和合法性均由店铺经营者负责。谷瀑提醒您购买商品/服务前注意谨慎核实,如您对商品/服务的标题、价格、详情等任何信息有任何疑问的,请在购买前通过谷瀑与店铺经营者沟通确认;谷瀑上存在海量店铺,如您发现店铺内有任何违法/侵权信息,请在谷瀑首页底栏投诉通道进行投诉。