• 安捷伦HJ T 36-1999 固定污染源排气中丙烯醛的测定15%聚乙二醇-20M柱3m*3.14

    详细信息

     品牌:安捷伦  型号:3m*3.14  加工定制:是  
     规格:3m*3mm  长度:3000  内径:3  
     膜厚:2.0  15%聚乙二醇-20M:Chromosorb W AW  HJ_T 36-1999:固定污染源排气  
     丙烯quan:乙醛  甲醇:氯乙烯  3%Dexil-300/Chromosorb W AW D:非甲烷总烃  

    HJ/T 36-1999标准中使用的15%聚乙二醇-20M/Chromosorb W AW DMCS 填充柱:

    特性 参数  
    固定液 15% 聚乙二醇-20M (PEG-20M)  
    担体 Chromosorb W AW DMCS (酸洗、硅烷化)  
    担体粒度 60-80目  
    常用规格 3 m × 3 .14mm (内径)  
    柱管材质 不锈钢、玻璃或聚四氟乙烯  
    *高使用温度 约200-250°C  
    应用 固定污染源排气中丙烯醛的测定 (HJ/T 36-1999)  
     

    名称:15%聚乙二醇-20M/Chromosorb W AW填充柱

    规格:3m*3mm,60-80目

    ZUI高温度:240°C

    应用:HJ_T 36-1999 固定污染源排气中丙xi醛的测定 气相色谱法

     

    浩瀚色谱(山东)应用技术开发有限公司,采用HJ1999丙xi醛测定PEG20M色谱柱赛默飞 测定固定污染源排气中丙xi醛

    面积外标法定量,在安捷伦,岛津,赛默飞,瓦里安,布鲁克,PE上安装使用,效果良好。

     

     

    适用于:

    安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890

    岛津GC-14C,GC-2010,GC-2014,GC-2030

    赛默飞1310,1300,1610,1600

    瓦里安3800系列

    布鲁克PE580,590,680,690

    磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓
     


    15% polyethylene glycol-20M/Chromosorb W AW DMCS packed column used in HJ/T 36-1999 standard:
    Characteristic parameters
    Fixed liquid 15% PEG-20M (PEG-20M)
    Chromosorb W AW DMCS (acid washing, silanization)
    Carrier particle size 60-80 mesh
    Common specifications: 3 m × 3.14mm (inner diameter)
    Column material: stainless steel, glass, or polytetrafluoroethylene
    The maximum operating temperature is about 200-250 ° C
    Determination of Acrolein in Exhaust Gas from Fixed Pollution Sources (HJ/T 36-1999)
    Name: 15% Polyethylene Glycol-20M/Chromosorb W AW Filled Column
    Specification: 3m * 3mm, 60-80 mesh
    ZUI high temperature: 240 ° C
    Application: HJ_T 36-1999 Determination of Propionaldehyde in Fixed Source Exhaust Gas by Gas Chromatography
    Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses HJ1999 formaldehyde determination PEG20M chromatographic column Thermo Fisher Scientific to determine formaldehyde in exhaust gas from fixed pollution sources,
    The area external standard method for quantification has been installed and used on Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, and PE with good results.
    Suitable for:
    Agilent 490 online/portable, 48905890689088608890
    Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
    Thermo Fisher Scientific 1310130016101600
    Varian 3800 Series
    Brooke PE580590680690
    Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao